ACT 7 mobile
air conditioner
-
ACT 7 standard setup
-
ACT 7 indoor unit
-
ACT 7 outdoor unit
Mobile water-cooled air conditioner for fast and efficient temporary cooling
When in need of temporary small-scale cooling, an efficient and easily implemented solution is required. The ACT 7 mobile water-cooled air conditioner can deliver efficient cooling in a matter of minutes with no cooling knowledge or special training required to install the unit.
Find your local ACT 7 distributor here
Ideal for rental companies and event organisations
Whether the requirement is to cool down a retail space, marquee, warehouse or even an office where the existing air-conditioning system has broken down, the ACT 7 will get the job done. With its robust and lightweight build, it is ideally suited to withstand the wear and tear characterising the rental market.
Whole-room cooling
In contrast to most air-cooled units, the ACT 7 will provide whole-room cooling without the need to continually exhaust internal air.
In addition, the unit does not require mounting of an exhaust air duct to an outside wall. Getting the ACT 7 up and running is simply a matter of connecting the cooling line connectors to the outdoor heat rejection unit.
How it works
The ACT 7 absorbs the heat into a refrigerant cooling system. From there, the heat is transferred to the self-containing chilled water/glycol system. It is then pumped through to the outdoor unit where the water is cooled and the heat dissipates.
The indoor unit is connected to the outdoor unit via two 22mm quick-connect, self-sealing flexible hoses. These hoses are supplied in 5m or 15m lengths and can be connected to a maximum length of 30m.
or quote
- Rental companies
- Event organizers
- Facility Management
- Server rooms
- Data centres
- Temporary buildings
- Tents
- Retail premises
- Offices
- Workshops
- Fitness rooms
- Industrial kitchens
- Cold room cooling (temporary)
- High-efficiency cooling circuit
- No cooling knowledge required for installation
- Castor-mounted, rugged metal construction
- Quick-connect cooling line connectors
- Indoor unit with stepless variable fan speed and adjustable grille
- Compact outdoor heat exchanger
- Outdoor heat rejection unit with variable temperature-dependent fan
speed (EU only) - Only water/glycol hose connection required between indoor and
outdoor units - Refrigerant-free line connection between indoor and outdoor units
- Peristaltic condensate pump with 10-metre head and high-level alarm
- Up to 30 metre installation distance between indoor and outdoor units
- High-gloss paint (easier cleaning)
- 230V CEE 7/7 power supply (EU only
Control Panel
- A - Cooling mode switch:
Select either ‘recirculation’ or ‘air-conditioning’ mode. In ‘air-conditioning’ mode, the electronic thermostat automatically controls the room temperature at the cooling set point from 8°C to 35°C. - B - LCD Display panel:
Shows the actual and set point temperature, operation modes and equipment status including any alarms. The cooling set point can be adjusted using the display. - C - Fan speed control dial:
Stepless adjustment of air flow for maximum comfort.
Model | ACT 7 (EU) | ACT 7 (UK) | |
---|---|---|---|
Cooling capacity (max.) (Outside conditions 28°C/60%RH) | kW | 7.0 | 7.0 |
Power supply | V/Hz | 230/1ph/50 | 230/1ph/50 |
Fuse | A | 16.0 | 13.0 |
Nominal running current | A | 11.2 | 11.0 |
Nominal power consumption | kW | 2.6 | 2.5 |
Power plug | CEE 7/7 | UK mains | |
Airflow, internal (stepless variable) | m³/h | 930-1,310 | 930-1,310 |
Automatic cooling thermostat | Yes | Yes | |
Defrost mode | Automatic hot gas injection | Automatic hot gas injection | |
Sound level at 3m distance (min. speed) | dBA | 53 | 53 |
Sound level at 3m distance (max. speed) | dBA | 56 | 56 |
Operating range – inside temperature | °C | 8-35 | 8-35 |
Operating range – outside temperature | °C | 0-40 | 0-40 |
Product size (H x W x D) | mm | 1,070 x 852 x 420 | 1,070 x 852 x 420 |
Weight | kg | 117 | 117 |
Package size (H x W x D) | mm | 1,150 x 920 x 440 | 1,150 x 920 x 440 |
Weight including package | kg | 125 | 125 |
Refrigerant/charge | gram | R407C/880 | R407C/880 |
GWP (Global Warming Potential) | 1,774 | 1,774 | |
CO2 equivalent | ton | 1,561 | 1,561 |
Max. length between in- and outdoor unit | m | 30 | 30 |
Max. head | m | 10 | 10 |
Automatically pumps out condensed water | Yes, peristaltic pump | Yes, peristaltic pump | |
Filter inside | Yes, cleanable | Yes, cleanable | |
Quick-connection couplings, water ½” | Yes, open face | Yes, open face | |
Water/glycol circuit | Prefilled 33% monoethylene glycol mix | Prefilled 33% monoethylene glycol mix | |
Thermoplastic rubber elastomer castors | 4 turnable 75mm castors, two with brake | 4 turnable 75mm castors, two with brake | |
Maneuvering | 2 strong handles | 2 strong handles | |
Design | Hot-galvanized steel plates | Hot-galvanized steel plates | |
Surface powder coating | RAL7047 Gloss 85 smooth | RAL7047 Gloss 85 smooth | |
Outdoor unit | |||
Airflow, variable | Yes | No | |
Sound level at 3m distance (min. speed) | dBA | 33 | 52 |
Sound level at 3m distance (max. speed) | dBA | 55 | 52 |
Wall placement | Yes, 2 chains with hooks included (L 650mm) | Yes, 2 chains with hooks included (L 650mm) | |
Ground placement | Yes, 4 built-in rubber feet | Yes, 4 built-in rubber feet | |
Product size (H x W x D) | mm | 520 x 560 x 310 | 520 x 560 x 310 |
Weight | kg | 18.5 | 18.0 |
Package size (H x W x D) | mm | 533 x 574 x 329 | 533 x 574 x 329 |
Weight including packaging | kg | 19.5 | 19.0 |
Bleeder screw | Yes | Yes |
-
ACT 7 indoor unit with handles
-
Castor mounted, rugged metal construction
-
Outdoor heat reject unit with automatically adjusting variable speed EC fan
-
Quick and easy installation
-
Quick connect interconnecting hoses.
-
Control panel and adjustable air outlet grille
-
ACT 7 installed in a workshop
-
ACT 7 installed in an office setting
-
ACT 7 cooling down a gym
-
ACT 7 cooling a server room
-
Single outdoor unit installation
-
T-split connecting two outdoor units to one indoor unit for extended operational range ≥ 40°C
- 5 or 15 metre connection hoses (max total of 30 metres per unit)
- T-split for connection of two outdoor units to one indoor unit for extended operational range ≥ 40°C
- Duct spigot kit
- Forklift guides